Features
- Bright, large 5” Color TFT LCD for better readability of all parameters.
- Intuitive user interface.
4 models available:
- SpO2 only (Model #SPLF-OX)
- SpO2 + NIBP (Model #SPLF-NP)
- SpO2 + Mainstream CO2 (Model #SPLF-MC)
- SpO2 + Sidestream CO2 (Model #SPLF-SE)
Selectable Display Modes:
– digits only, showing parameters values
– digits and graphs, showing real-time plethysmogram and capnogram/NIBP (according to model)
– digits, graph and trends, displaying in addition the historical values.
– 9 LED indicators to easily control patient type, units, power and alarm status.
– New patient presets allowing a one step action to set all alarms limits according to patient type (Adult, Child, Neonate).
– 360° Visible and Audible alarms.
– Over 72h trend data with a 1 min resolution.
– Built-in power supply and 2400mAh lithium battery for 6h continuous monitoring.
– Extension port upon request for custom protocols, raw data output for research and other device connectivity.
– Bluetooth printer connectivity for record printouts.
– USB port for easy updates with new software functions (further connectivity and control options, addition of peripherals).
Functions
Oximetry (all models)
– Real-time measurement of SpO2, pulse rate (PR), perfusion index (PI), and Variability of Pulse Index (PIV).
– Real-time photoplethysmogram display
– High accuracy and reliability even with low blood perfusion down to 0.05%, allowing application in OR, ICU and NICU.
NIBP (SPLF-NP model)
– Measurement of Systolic BP, Mean Arterial Pressure, Diastolic BP using oscillometric method.
– 3 measurement modes such as manual, auto and continuous.
– hardware and software over-pressure protection
Capnography (SPLF-SE and SPLF-MC models)
– Measurement of EtCO2, FiCO2 and Respiratory Rate (awRR)
– Real-time capnogram display
– Automatic barometric pressure, temperature compensation and manual anaesthetic gases compensation
– Fixed Micro Flow: 50 ml/min (±10ml/min) (SPLF-SE Model only)
Thermometry (Option TBD):
– Body temperature measurement using Fast temperature probe
– Environmental characteristics
Operating Conditions
– Temperature: 0°C ~ 40°C
– Humidity: 15 ~ 95%, non-condensation
– Atmospheric pressure: 70.0kPa ~ 106.0kPa
Storage Conditions
– Temperature: -20 ~ 70°C (4 to 158°F)
– Humidity: 15 ~ 95%, non-condensation
– Atmospheric pressure: 57.3kPa ~ 106.0kPa
Electrical and Mechanical characteristics
Electrical Power Supply
– AC: 100 ~ 240V ± 10% (built-in adapter)
– Input power: 60VA
– Frequency: 50Hz/60Hz ± 3Hz
– One equipotential grounding interface
– Product Class: IIb (in accordance with MDD93 /42/ EEC)
Battery
– Built-in rechargeable lithium batteries: 11.1 V / 2400mAh
– Mechanical
– Dimensions: 255 x 140 x 95mm (LxWxH)
– Weight: < 2kg (without accessories)
Interfaces
Connectivity
– USB interface
– RS232 DB9 interface
HMI
– Five buttons: Power switch, alarm stop, alarm pause, up and down buttons, menu
– Display: 5” Color TFT LCD, 800 x 480pixels
– Audio/Visual Indicators: Alarm limit reached, Alarm tone, Alarm mute, pulse strength, Patient name, Patient Type, Time, battery status, connection status.
– LEDs: Adult, Neonate, Pressure Unit or SpO2/PR (according to model), battery in use, battery charging, silenced alarm.
– User Interface language: English, French, Italian, Hungarian (additional language upon request).
Performances
SpO2 (all models)
– Sp02: Measurement Range: 0 – 100%; Accuracy Range: from 70 – 100 % = ±2%, below 70%, Undefined; Resolution: 1%
– Pulse Rate: Measurement Range: 15-300 BPM; Accuracy Range: ±2%; Resolution: 1 bpm
– PI: Measurement Range: 0-20%; Resolution: 0.001%
– PIV: Measurement Range: 0-100%; Accuracy Range: Undefined; Resolution: 1%
NIBP (SPLF-NP model only)
– Method: Automatic oscillometric
– Operation modes: Manual, Automatic, Continuous
– Automatic mode measurement interval: 1min, 2min, 3min, 4min, 5min, 10min, 15min, 30min, 60min, 90min, 2h, 3h
– Continuous mode measurement period: 5mins, with 5s between each measurement
– Maximum single measurement time: 180s
Measurement range:
– Systolic BP: Adult mode: 40 ~ 270 mmHg, Pediatric mode: 40 ~ 200 mmHg
– Diastolic BP: Adult mode: 10 ~ 210 mmHg, Pediatric mode: 10 ~ 150 mmHg
– MAP: Adult mode: 20 ~ 230 mmHg, Pediatric mode: 20 ~ 165 mmHg
– Accuracy: Mean error: ±5mmHg, Standard deviation: 8mmHg
– Static pressure measurement range: 0 mmHg (0kPa) ~ 300mmHg (39.9kPa)
– Static pressure measurement accuracy: ±2mmHg or ±1% of reading (Whichever is greater)
Resolution: 1 mmHg
Initial inflation pressure setting range: Adult mode: 80 ~ 280 mmHg, Pediatric mode: 80 ~ 210 mmHg
Initial inflation pressure default: Adult mode: 160 mmHg, Pediatric mode: 140 mmHg
Software over-pressure protection: Adult mode: 297 ±3mmHg, Pediatric mode: 240 ±3mmHg
Alarm range:
– Systolic BP: Adult mode: 40 ~ 270 mmHg, Pediatric mode: 40 ~ 200 mmHg
– Diastolic BP: Adult mode: 10 ~ 210 mmHg, Pediatric mode: 10 ~ 150 mmHg
– MAP: Adult mode: 20 ~ 230 mmHg, Pediatric mode: 20 ~ 165 mmHg
Capnography (SPLF-MC and SPLF-SE models)
Method: Infrared radiation absorption technology
CO2 measurement range: 0 ~ 20 %
Accuracy:
0 ~ 12% : ±(0.2 Vol% + 2% of reading),
– 12 ~ 20% : ±(0.2 Vol% + 6% of reading)
Measurement accuracy drift: accuracy requirements within 6 hours
Resolution: 0.1 Vol%
Accuracy: Mean error: < ±5mmHg, Standard deviation: < 8mmHg
Apnea alarm delay time: 20s, 25s, 30s, 35s, 40s, 45s, 50s, 55s, 60s
Alarm range:
– EtCO2: 0 ~ 150mmHg
– FiCO2: 0 ~ 150mmHg
– AwRR: 0 ~ 150rpm